Melanotan I lot KB-34289 certificate of analysis

10 mg vial. Tested by ILS Laboratories: purity 97.55% by HPLC-UV, identity confirmed by HPLC-RTM, net content 10.13 mg. Reported September 12, 2026.

Sample summary

ProductMelanotan I 10 mg
LotKB-34289
Purity (HPLC-UV)97.55%
Identity (HPLC-RTM)Confirmed
Net content10.13 mg (+1.3% vs. label)
AppearanceGood (visual)
EndotoxinNot tested for this lot
Microbial analysis (PCR)Not tested for this lot

Laboratory record

Testing laboratoryILS Laboratories
Client on certificateKlow.bio
Accession numberACC-2026-18994
Certificate numberCOA-2026-KDMU29
Lab verification access codeAG2LHQYW
Received by labSeptember 9, 2026
ReportedSeptember 12, 2026
Release specificationPurity ≥95%; identity confirmed
Against stated specificationMeets

The client listed on the certificate, Klow Labs LLC (klow.bio), is the company that operates MT1 Labs.

Analytical results and methods

TestMethodResult
IdentityHPLC retention-time comparison with a reference standard (HPLC-RTM)Confirmed
PurityHPLC with UV detection (area percent)97.55%
Net contentQuantitation by the laboratory10.13 mg
Bacterial endotoxinLimulus amebocyte lysate (USP <85>)Not tested
Microbial DNAPolymerase chain reaction (PCR) for common microbial contaminantsNot tested
FentanylImmunoassay, 50 ng/mL cutoffNot detected

Verify this certificate

Accession number ACC-2026-18994, Certificate number COA-2026-KDMU29.

  1. Find the lot number on your vial. It is printed on the label, for example KB-34289.
  2. Look it up. Enter it at mt1.bio/verify, or open the matching lot in the COA archive.
  3. Check the lab's own record. Go to portal.ils-lab.com (or scan the QR code on the certificate) and enter the lot's verification access code, listed on its lot page, to view the laboratory's own copy of the certificate.
  4. Compare the details. Lot number, the laboratory’s reference numbers, purity and dates should match exactly.

What a certificate of analysis does and doesn't show

  • A COA reports the identity, purity and content of the specific sample tested, on its test date. Results apply to that lot only.
  • HPLC purity measures the main peak relative to other detected components. It does not identify the peak on its own; the separate identity test (HPLC retention-time match) does that.
  • A retention-time match shows the main peak behaves like the reference standard under one method. It is not a mass or structure measurement.
  • Endotoxin and microbial results apply only where those tests appear on the certificate. Lots without them are marked "Not tested".
  • A certificate does not establish stability after the test date or suitability for any particular purpose.

Other Melanotan I lots

LotVial sizeNet contentPurity (HPLC-UV) Identity (HPLC-RTM)Endotoxin (LAL)Microbial (PCR)ReportedCOA
KB-34289 10 mg 10.13 mg 97.55% Confirmed Not tested Not tested View lot KB-34289

Testing laboratory: ILS Laboratories. Release specification: purity ≥95% by HPLC-UV with identity confirmed by HPLC retention-time match against a reference standard. Results apply only to the lot listed. Certificates list the testing client as Klow.bio / Klow Labs LLC, the company that operates MT1 Labs.